---
product_id: 252633253
title: "Electronics OTFPH-XPHPA-001-194"
brand: "elitech"
price: "NZ$18"
currency: NZD
in_stock: true
url: https://www.desertcart.nz/products/252633253-electronics-otfph-xphpa-001-194
store_origin: NZ
region: New Zealand
---

# 0.14oz/yr max sensitivity world's 1st TFT screen 6H continuous runtime Electronics OTFPH-XPHPA-001-194

**Brand:** elitech
**Price:** NZ$18
**Availability:** ✅ In Stock

## Summary

> 🎯 Detect leaks with precision and style — never miss a beat!

## Quick Answers

- **What is this?** Electronics OTFPH-XPHPA-001-194 by elitech
- **How much does it cost?** NZ$18 with free shipping
- **Is it available?** Yes, in stock and ready to ship
- **Where can I buy it?** [www.desertcart.nz](https://www.desertcart.nz/products/252633253-electronics-otfph-xphpa-001-194)

## Best For

- elitech enthusiasts

## Why This Product

- Trusted elitech brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Stay powered all day:** Built-in rechargeable lithium battery delivers 6 hours of continuous use with quick 4-hour recharge.
- • **Tailor your detection:** 3 selectable sensitivity levels (High/Medium/Low) for pinpoint control on all halogenated refrigerants.
- • **Work smarter, not harder:** Ergonomic, rugged design built to withstand tough HVACR environments and long workdays.
- • **See leaks like never before:** Innovative TFT display animates leak detection, battery, and sensor status for crystal-clear readings.
- • **Precision that lasts a decade:** Infrared sensor with 10-year lifespan ensures unmatched durability and accuracy.

## Overview

The Elitech ILD-200 is a cutting-edge refrigerant leak detector featuring a revolutionary infrared sensor with a 10-year lifespan, ultra-sensitive detection down to 0.14oz/yr, and the industry's first animated TFT screen for intuitive leak visualization. Designed for HVACR professionals, it combines rugged ergonomics with a 6-hour battery life and customizable sensitivity, making it the ultimate tool for fast, reliable, and precise leak detection.

## Description

Description:Like all of Elitech’s test instruments, the ILD-200 Advanced Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. We set out to develop the best refrigerant leak detector for HVACR.The ergonomic design fits naturally in your hand.The ruggedized construction stands up to abuse most other leak detectors can't handle.The Six-hour battery life lets you work all day before recharging.The sound and light alarm allow you to work the way you want to work.Parameter:Sensor principle: Infrared spectrum absorptionSensor life: 10 yearsSensitivity: max 4g/yrAlarm mode: sound and light alarm, TFT LCD displayAutomatic shutdown: 10 minutes without operationBattery: built-in rechargeable lithium battery 3.7V 3000mAhWorking time: continuous 6HCharging: 4 hoursOperating environment: -10°C - 52°C relative humidity (50%~85%RH)Storage temperature: -20°C to 60°C（-4°F to 140 °F）Weight: 415g(14.6oz)Size: 201mm*86mm*38mm(7.9*3.3*1.5)Certification: SAE J1627, SAE J2791, SAE J2913; EN14624: 2012; CE certification

## Features

- With the latest and most innovative infrared sensor, its sensor life extends enormously for a maximum of 10 years. It triggers on all halogenated refrigerants much more precisely than traditional corona sensors and moderate heat-diode sensors.
- 3 Selectable Sensitivity Levels -High/Medium/Low; With a maximum sensitivity up to 0.14oz/yr.
- The world's first TFT screen advanced leak detector animates leakage, sensitivity, battery levels and sensor faulty indicators and presents more clear and easy readings.
- Pressing PEAK button to mark the maximum leakage value during measurements.
- International products have separate terms, are sold from abroad and may differ from local products, including fit, age ratings, and language of product, labeling or instructions.

## Technical Specifications

| Specification | Value |
|---------------|-------|
| Manufacturer | Elitech |
| Part Number | ILD-200 |
| Product Dimensions | 8.38 x 3.81 x 20.07 cm; 421.84 g |
| Batteries | 1 Lithium Metal batteries required. (included) |
| Item model number | ILD-200 |
| Colour | Ild-200 |
| Style | Compact |
| Finish | Painted |
| Material | Plastic |
| Power Source | Battery Powered |
| Item Package Quantity | 1 |
| Batteries included? | Yes |
| Batteries Required? | Yes |
| Battery Cell Type | Lithium Ion |
| Item Weight | 422 g |

## Product Details

- **Brand:** Elitech
- **Style:** Compact
- **Power source:** Battery Powered
- **Colour:** Ild-200
- **Item weight:** 0.93 Pounds
- **Alarm:** Audible
- **Operating humidity:** 85 percent
- **Sensor type:** Non Dispersive Infrared
- **Material:** Plastic
- **Manufacturer:** Elitech

## Images

![Electronics OTFPH-XPHPA-001-194 - Image 1](https://m.media-amazon.com/images/I/613dkPvMCTL.jpg)
![Electronics OTFPH-XPHPA-001-194 - Image 2](https://m.media-amazon.com/images/I/719hcGqzZ9L.jpg)
![Electronics OTFPH-XPHPA-001-194 - Image 3](https://m.media-amazon.com/images/I/71sFhhg4kAL.jpg)
![Electronics OTFPH-XPHPA-001-194 - Image 4](https://m.media-amazon.com/images/I/71S9sjA8hiL.jpg)
![Electronics OTFPH-XPHPA-001-194 - Image 5](https://m.media-amazon.com/images/I/718pqp9AiBL.jpg)

## Questions & Answers

**Q: What are the features of the infrared IR sensor in ILD-200/300?**
A: The infrared IR sensor's sensitivity remains stable for 10 years, unaffected by humidity or oil, and nearly equal for most refrigerants. It detects concentration changes, so the wand must keep moving.

**Q: What are the features of the heated diode sensor in ILD-100H?**
A: The heated diode sensor detects absolute concentration levels, allowing sustained beeping at leaks and high initial sensitivity. However, it loses sensitivity over time, requires replacement, and shows varied sensitivity to refrigerants.

**Q: How long does the sensor last?**
A: If it seems like your leak detector is no longer picking up leaks or is not as sensitive as it was when you first bought it, try replacing the filter. This should fix the issue. If this does not fix the issue try replacing the sensor.

**Q: Why is it necessary to move during the detection process?**
A: As ILD series are designed to detect the relative concentration of gases, that if the detected concentration remains unchanged in the stationary environment, it will not be able to pinpoint the leakages.

**Q: Why does the product alarm when not in a leaking environment?**
A: 1. Deformation of the optical chamber affects detection data, a normal occurrence. 2. Loose critical optical filters, we could provide repair assistance. 3. Check for routers or devices causing electromagnetic interference.

## Frequently Bought Together

- Elitech HVAC Refrigerant Leak Detector 10 Yrs Infrared Sensor Life, Halogen Freon Sniffer, Air Conditioning Detection, Automotive Gas Finder, ILD-200
- Elitech Wireless Digital Manifold Gauge Set Data Logging Refrigerant HVAC Gauges with Hoses, Temperature Clamps, LMG-10W
- Elitech LMC-100F+ Refrigerant Charging Weight Scale 110Lbs Freon Scale High Precision for HVAC with Case

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.nz/products/252633253-electronics-otfph-xphpa-001-194](https://www.desertcart.nz/products/252633253-electronics-otfph-xphpa-001-194)

---

*Product available on Desertcart New Zealand*
*Store origin: NZ*
*Last updated: 2026-04-27*